Chapter 701 — Construction Contractors and Contracts
ORS 701.555 Barrier-type exterior insulation and finish systems
As used in this section, “barrier-type exterior insulation and finish system” means a foam insulation board inner layer, a polymer and cement base coat middle layer reinforced with glass fiber mesh and a textured finish coat exterior layer, in which:
The layers are bonded to the outside face of an exterior wall;
The middle or exterior layer, but not the inner layer, provides a water resistant barrier for the exterior of the building envelope;
The layers do not provide a means of drainage for water that accumulates behind the exterior surface; and
The layers insulate the building.
A person licensed or required to be licensed under this chapter may not install a barrier-type exterior insulation and finish system on:
A new building; or
An existing building, except as necessary to repair or replace a previously installed barrier-type exterior insulation and finish system.
Subsection (2) of this section does not apply to the application of a barrier-type exterior insulation and finish system:
As an architectural feature that is not intended to protect an interior space of the building; or
To a concrete wall or a concrete masonry unit block wall.
NOTICES OF DEFECT IN RESIDENCE
Official sources · 2Tap to view provenance and version history
Provenance
2025 Oregon Revised Statutes — official online source
Official online edition
- Source
- oregonlegislature.gov
- SHA-256
1795680e…503dbac7- Review
- auto verified
Version history
Earlier statutory text is available in an ingested published ORS edition.
2025 Oregon Revised Statutes — official online source · active · operative text
Official source2023 Oregon Revised Statutes · active · operative text
Official source